Package Contents

UniFi Switch
Rack-Mount Brackets (Qty. 2)
Bracket Screws (Qty. 8)
Mounting Screws (Qty. 4)
Cage Nuts (Qty. 4)
Power Cord

System Requirements

IMPORTANT: We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.

Hardware Overview

Touchscreen Display

Bootup Animation

Initializing.

Steady White

Factory defaults, waiting for adoption.

Steady Blue

Successfully adopted by a network and working properly.

Location Animation

This indicates that you clicked Locate in the UniFi Network Application. The Application will also display the location of the device on the map.

RJ45 PoE LED (Ports 1 - 8)

Off

No PoE

Amber

802.3af/at PoE

RJ45 Speed/Link/Activity LED (Ports 1 - 16)

Off

No Link

Amber

Link Established at 10/100 Mbps

Flashing Indicates Activity

Green

Link Established at 1000 Mbps

Flashing Indicates Activity

SFP Speed/Link/Activity LED (Ports 17 - 18)

Off

No Link

Green

Link Established at 1 Gbps

Flashing Indicates Activity

RJ45 (Ports 1 - 8)

RJ45 ports support 10/100/1000 Ethernet connections and 802.3af/at PoE output.

RJ45 (Ports 9 - 16)

RJ45 ports support 10/100/1000 Ethernet connections.

SFP (Ports 17 - 18)

Hot-swappable SFP ports support 1 Gbps connections.

Reset Button

This button serves two functions for the UniFi Switch:

  • Restart Press and release the Reset button quickly.
  • Restore to Factory Default Settings Press and hold the Reset button for more than five seconds.

Power Port

Connect the included Power Cord to the Power port.

Installation Requirements

Hardware Installation

IMPORTANT: Fanless switches must not be stacked. Do not place this UniFi Switch on top of another switch. Do not place anything on top of this UniFi Switch.

  1. OR

Connecting Power

Connecting Ethernet

Note: If you are connecting PoE devices, check the display to see how much PoE wattage is available.

Connecting SFP

For information about compatible fiber SFP modules, visit: ubnt.link/UniFi_SFP_DAC_Compatibility

Specifications

USW-16-POE

Dimensions

442.4 x 200 x 43.7 mm
(17.42 x 7.87 x 1.72")

Weight

2.80 kg (6.17 lb)

With Rackmount Brackets2.89 kg (6.37 lb)

Interfaces

Networking(16) 10/100/1000 RJ45 Ports
(2) 1G SFP Ethernet Ports
ManagementEthernet In-Band

Power Method

100-240VAC/50-60 Hz, Universal Input

Power Supply

AC/DC, Internal, 60W

Supported Voltage Range

100 to 240VAC

Max. Power Consumption
(Excluding PoE Output)

18W

LEDs

SystemStatus
RJ45 Data PortsPoE; Speed/Link/Activity
SFP Data PortsLink/Activity

ESD/EMP Protection

Air: ± 16 kV, Contact: ± 12 kV

Shock and Vibration

ETSI300-019-1.4 Standard

Operating Temperature

-5 to 40° C (23 to 104° F)

Operating Humidity

10 to 90% Noncondensing

Certifications

CE, FCC, IC

PoE

PoE Interfaces

Ports 1-8POE+ IEEE 802.3af/at
(pins 1, 2+; 3, 6-)

Max. PoE Wattage per Port by PSE

802.3at32W

Voltage Range 802.3af Mode

44-57V

Voltage Range 802.3at Mode

50-57V

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

Warning

WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.

Warning

WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.

Warning

WARNING: Do not use this product in location that can be submerged by water.

Warning

WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    1. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    2. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    3. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    4. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    5. Protective bonding must be installed in accordance with local national wiring rules and regulations.

Limited Warranty

ui.com/support/warranty

The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada

CAN ICES-3(A)/NMB-3(A)

Australia and New Zealand

RCM

Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.

CE Marking

CE marking on this product represents the product is in compliance with all directives that are applicable to it.

CE

WEEE Compliance Statement

Declaration of Conformity

Online Resources

SupportCommunityDownloads