Click for
Table of Contents

menuUAP, UAP-LR Quick Start Guide

Package Contents

UniFi AP
Mounting Bracket
Ceiling Backing Plate
Flat Head Screws (Qty. 3)
Keps Nuts (Qty. 3)
Screws (Qty. 3)
Screw Anchors (Qty. 3)
PoE Adapter (24V, 0.5A) with Mounting Bracket
Power Cord

Installation Requirements

System Requirements

Hardware Overview

LED

Ports

Ethernet

The 10/100 Ethernet port is used to connect the power and should be connected to the LAN and DHCP server. Power can be provided by any of the following:

  • Included PoE Adapter
  • Ubiquiti UniFi Switch with PoE
  • Ubiquiti TOUGHSwitchPRO

Reset

The Reset button serves two functions for the UniFi AP:

  • Restart Press and release the Reset button quickly.
  • Restore to Factory Default Settings Press and hold the Reset button for more than five seconds until the LED turns off.

Locking Clip

During installation, the Locking Clip on the Mounting Bracket locks into the Locking Notch on the UniFi AP to help prevent theft.

Mounting Bracket

This bracket is used for wall or ceiling mounting.

Hardware Installation

Wall Mount

  1.  
  2. Optional

  3.  
  4. Optional

    Note: If the Ethernet cable feeds along the mounting surface, then remove the Cable Feed Plug on the side of the UniFi AP instead.

Ceiling Mount

Connecting Power

Note: The UAP/UAP-LR uses 24V passive PoE. PoE must be manually enabled on the switch.

OR

Optional

Specifications

UAP/UAP-LR

Dimensions

200 x 200 x 36.5 mm
(7.87 x 7.87 x 1.44")

Weight

290 g (10.23 oz)

with Mounting Kit430 g (15.17 oz)

Networking Interface

(1) 10/100 Ethernet Ports

Buttons

Reset

Power Method

Passive Power over Ethernet (12-24V)

Power Supply

24V, 0.5A PoE Adapter (Included)

Power Save

Supported

Operating Frequency

UAP2.4 GHz
UAP-LR2.4 GHz

Max. Power Consumption

UAP4W
UAP-LR6W

Max. TX Power

UAP20 dBm
UAP-LR27 dBm

Antenna

Integrated Omni

Antenna Gain

4 dBi

Wi-Fi Standards

802.11 b/g/n (2.4 GHz)

Wireless Security

WEP, WPA-PSK,

WPA-Enterprise (WPA/WPA2, TKIP/AES)

BSSID

Up to Four per Radio

Mounting

Ceiling/Wall (Kits Included)

Operating Temperature

-10 to 70° C (14 to 158° F)

Operating Humidity

5 - 80% Noncondensing

Certifications

CE, FCC, IC