Package Contents
![]() |
---|
NanoBeamM5 |
![]() |
---|
Ball Joint Mount |
![]() |
---|
Lock Ring |
![]() |
---|
Metal Strap |
![]() |
---|
PoE Adapter (24V, 0.5A) |
![]() |
---|
Power Cord |
Installation Requirements
The NanoBeam can be mounted on a pole or to a wall. A Metal Strap (included) is used for pole-mounting. For wall-mounting, a suitable fastener such as a screw or bolt (not included) is required.
- 7 mm socket wrench or screwdriver (for pole-mounting)
- Wall fastener (for wall-mounting)
- Shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE.
We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable
Hardware Overview
![]() Reset Button |
---|
To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the PoE Adapter. |
![]() Ethernet Port |
The Ethernet port is a PoE port used for data and power. It should be connected to the LAN and DHCP server. Power can be provided by any of the following:
|
![]() Power LED |
The Power LED will light blue when the device is connected to a power source. |
![]() Ethernet LED |
The Ethernet LED will light steady blue when an active Ethernet connection is made and flash when there is activity. |
![]() Signal LEDs |
In airOS®, you can modify the wireless signal strength threshold values for each LED on the Advanced tab under Signal LED Thresholds. The default values are shown below: |
Hardware Installation
Go to the appropriate mounting instructions: Pole Mounting or “Wall-Mounting”.
Pole-Mounting
Wall-Mounting
The NanoBeam must be mounted directly to a wood stud or other structurally stable surface to avoid damage to the mounting hole when you adjust the aim.
Optional Accessory
To enhance stability, you can use the NanoBeam Wall Mount Kit, model NBE-WMK (sold separately).
|
Note: Center screw included. Two optional screws (not included) provide additional stability. |
---|
Installation Instructions
Fastener (not included) |
OR |
NanoBeam Wall Mount Kit |
Aiming
Connecting Power
OR
Accessing airOS
Verify connectivity in the airOS® Configuration Interface.
- Make sure that your host machine is connected via Ethernet to the device.
- Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
- Launch your web browser and type https://192.168.1.20 in the address field. Press enter (PC) or return (Mac).
- Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use and the Ubiquiti Firmware License Agreement to use the product. Click Login.
The airOS Configuration Interface will appear, allowing you to customize your settings as needed. For additional details on the airOS Configuration Interface, refer to the User Guide available at ui.com/download/airmax-m
You can also manage your device using the Ubiquiti Internet Service Provider. Setup using the UISP™ app requires the U-Installer, sold separately.
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local country regulatory requirements.
The Output Power field is provided to the professional installer to assist in meeting regulatory requirements.
Specifications
NBE-M5-19 |
|
Dimensions (Mount Included) |
189 x 189 x 125 mm (7.44 x 7.44 x 4.92 in) |
---|---|
Weight (Mount Included) |
530 g (18.7 oz) |
Gain |
19 dBi |
Networking Interface |
(1) 10/100 Ethernet Port |
Enclosure |
Outdoor UV Stabilized Plastic |
Max. Power Consumption |
8W |
Power Supply |
24V, 0.5A PoE Adapter (Included) |
Power Method |
Passive PoE (Pairs 4, 5+; 7, 8 Return) |
Wind Loading |
45.4 N @ 200 km/h (10.2 lbf @ 125 mph) |
Wind Survivability |
200 km/h (125 mph) |
Mounting (Kit Included) |
Pole-Mount (Kit Included) |
Operating Temperature |
-40 to 70° C (-40 to 158° F) |
Operating Humidity |
5 to 95% Noncondensing |
Salt Fog Test |
IEC 68-2-11 (ASTM B117), |
Vibration Test |
IEC 68-2-6 |
Temperature Shock Test |
IEC 68-2-14 |
UV Test |
IEC 68-2-5 at 40° C (104° F) |
Wind-Driven Rain Test |
ETS 300 019-1-4 |
Certifications |
CE, FCC, IC |
Operating Frequency (MHz) |
||||
Worldwide |
5150 - 5875 |
|||
---|---|---|---|---|
US/CA |
U-NII-1 |
5150 - 5250 |
||
U-NII-2A |
5250 - 5350 |
|||
U-NII-2C |
5470 - 5725 |
|||
U-NII-3 |
5725 - 5850 |
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water. |
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. |
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
- Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
- The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
- Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
- Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
- Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(A)/NMB-3(A)
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
- l’appareil ne doit pas produire de brouillage;
- l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Le présent émetteur radio a été approuvé par ISDE Canada.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE
Radiation Exposure Statement
- This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
- This equipment should be installed and operated with minimum distance 113 cm between the radiator and your body.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
AVIS IMPORTANT
Déclaration sur l’exposition aux rayonnements
- Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans un environnement non contrôlé.
- Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y ait une distance minimale de 113 cm entre l’élément rayonnant et vous.
- Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre émetteur, et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. |
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados. |
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
![]() | Country List | |||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||
BFWA (Broadband Fixed Wireless Access) members noted in blue |
Note: This device meets Max. TX power limit per ETSI regulations. |
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz frequency range within all member states. |
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states. Other countries listed may use the 5.8 GHz frequency band. |
WEEE Compliance Statement
Declaration of Conformity
Online Resources
![]() | ![]() | ![]() |