Package Contents
NanoStation loco |
Zip Tie |
Installation Requirements
- Shielded Category 5 (or above) cabling with drain wire should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE.
We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable
- Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation loco and the other at the entry point to the building. The ETH-SP will absorb power surges and safely discharge them into the ground.
Diagram Showing Use of Ethernet Surge Protectors
Hardware Overview
Port View
Power LED |
---|
The Power LED will light blue when the device is connected to a power source. |
Ethernet Port |
10/100/1000 Ethernet port used to connect the power and should be connected to the LAN and DHCP server. |
Reset Button |
To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. |
Hardware Installation
Pole Mount
Connecting Power
WARNING: The switch port must comply with the power specifications listed in this “Specifications”. |
Accessing airOS via Wi-Fi
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements.
The Output Power field is provided to the professional installer to assist in meeting regulatory requirements.
Specifications
Loco5AC |
|
Dimensions |
179 x 77.5 x 59.1 mm |
---|---|
Weight |
180 g (6.35 oz) |
Processor |
MIPS 74K |
Memory |
DDR2 64 MB |
Antenna Gain |
13 dBi |
Networking Interface |
(1) 10/100/1000 Ethernet Port |
Power Method |
Passive PoE 2-Pair (Pairs 4, 5+; 7, 8 Return) |
Power Supply |
24V, 0.3A Gigabit PoE Supply* |
Max. Power Consumption |
7W |
Supported Voltage Range |
24V ±10% |
ESD/EMP Protection |
±24kV Contact / Air |
Operating Temperature |
-40 to 70° C (-40 to 158° F) |
Operating Humidity |
5 to 95% Noncondensing |
Certifications |
CE, FCC, IC |
* Not included. Recommended PoE Adapter: POE-24-12W-G.
Operating Frequency (MHz) |
||
Worldwide |
5150 - 5875 |
|
---|---|---|
US/CA |
U-NII-1 |
5150 - 5250 |
U-NII-2A |
5250 - 5350 | |
U-NII-2C |
5470 - 5725 | |
U-NII-3 |
5725 - 5850 |
Management Radio (MHz) |
|
Worldwide |
2412 - 2472 |
---|---|
US/CA |
2412 - 2462 |