Package Contents

ETH-SP-G2
M5 Self-Tapping Screw
M5 Serrated Washer

Hardware Overview

ETH IN/OUT Port

Passive surge-protected RJ45 Ethernet ports.

Grounding Point

The ETH-SP-G2 must be grounded by one of the following methods:

  • Using the included Self-Tapping Screw to ground the ETH-SP-G2 directly to a grounded metal pole or structure; and using STP cable.
  • Using an M5 machine screw and nut (not included) to attach a drain wire that is connected to a remote grounding block or structure.

Installation Requirements

Mounting accessories and optional drain wire are not included.

Pole-Mounting:

Wall-Mounting:

Optional: Drain wire, M5 machine screw, and nut are not included.

Note: Place the included Serrated Washer between the screw and drain wire.

Installation

Install the ETH-SP-G2 near an Ethernet device. Follow the appropriate steps for your installation:

Pole Mounting

A metal strap or cable tie is not included.

  1. Note: If the Ethernet device is mounted on the pole with a metal strap, you may use the same strap to attach the ETH-SP-G2.

  2. Note: If you are using a drain wire for grounding, proceed to “Connecting Ethernet”.

  3. Proceed to “Connecting Ethernet”.

Wall Mounting

Connecting Ethernet

Specifications

ETH-SP-G2

Dimensions

91 x 61 x 32.5 mm
(3.58 x 2.4 x 1.28
")

Weight

80 g
(2.82 oz)

Interface Connections

(2) RJ45 Female Connectors

ESD/EMP Protection

Absorbing Transient Current with Response to Surge Voltage from 100V/s to 1kV/µs

DC Spark-Over Voltage

90V @ 100V/s

Maximum Impulse Spark-over Voltage

700V @ 1kV/µs

Discharge Current

15kV

Maximum Insulation Resistance

1GΩ @ 50V

Maximum Capacitance

1.0 pF @ 1 MHz

Data Line Protection

RJ45 10/100/1000 Ethernet

IEEE 802.3af PoE Support

Yes

Shock and Vibration Certification

ETSI300-019-1.4 Standard

Operating Temperature

-30 to 65° C
(-22 to 149° F)

Operating Humidity

10 to 90% Noncondensing